RESEARCH ON TEMPERATURE AND HUMIDITY COMPENSATION OF SENSOR MEASURED VALUES MQ7


POPA SORIN EUGEN 1, PUIU PETRU GABRIEL 1
1. “Vasile Alecsandri” University of Bacau, Calea Marasesti 156, Bacau, 600115, Romania

Issue:

PLUMEE, Number 1, Volume V

Section:

Issue No.1 - Volume 5 (2015)

Abstract:

The paper aims to determine the mathematical formula to enable correction of the measured values of the sensor using MQ-7 with change in ambient temperature and humidity dependency curve provided by the sensor manufacturer.

Keywords:

MQ-7, carbon monoxide sensor, the error correction.

Code [ID]:

PLUMEE201501V05S01A0018 [0004257]

Full paper:

Download pdf