COMPARATIVE STUDY CONCERNING INTERNAL PRESSURE DIMENSIONING OF TALL TOWERS ACCORDING TO I.S.C.I.R. STANDARD AND A.S.M.E. STANDARD

  • BIBIRE LUMINIŢA
    UNIVERSITY OF BACĂU
  • COBREA CODRIN
    UNIVERSITY OF BACĂU

Abstract

Based on case studies, the authors realized a comparative study regarding internal pressure dimensioning and testing of tall towers to I.S.C.I.R. standard and A.S.M.E. standard. The following tall towers types were used to complete the study: CO2 stripper - Ammonia installation (S.C. SOFERT S.A., Bacau) and Cyclohexanon and Cyclohexanonoxyme stripper - Ammonium sulphate installation (S.C. FibrexNylon S.A. Chemical Division, Savinesti).

Cuvinte cheie

tall tower standard stripper cost price ASME ISCIR