COMPARATIVE STUDY CONCERNING INTERNAL PRESSURE DIMENSIONING OF TALL TOWERS ACCORDING TO I.S.C.I.R. STANDARD AND A.S.M.E. STANDARD

BIBIRE LUMINIŢA, COBREA CODRIN

UNIVERSITY OF BACĂU, ROMANIA

Abstract

Based on case studies, the authors realized a comparative study regarding internal pressure dimensioning and testing of tall towers to I.S.C.I.R. standard and A.S.M.E. standard. The following tall towers types were used to complete the study: CO2 stripper - Ammonia installation (S.C. SOFERT S.A., Bacau) and Cyclohexanon and Cyclohexanonoxyme stripper - Ammonium sulphate installation (S.C. FibrexNylon S.A. Chemical Division, Savinesti).

Keywords

tall tower standard stripper cost price ASME ISCIR