STUDY OF THE EXTRACTION IN A CONTACTOR EQUIPPED WITH A NEW TYPE OF PACKING

  • KONCSAG CLAUDIA IRINA
    “OVIDIUS” UNIVERSITY CONSTANTA, 124, MAMAIA BLD., 8700 CONSTANTA
    CKONCSAG@UNIV-OVIDIUS.RO
  • MAIORU GETA SIMONA
    “OVIDIUS” UNIVERSITY CONSTANTA, 124, MAMAIA BLD., 8700 CONSTANTA
  • TOIU ANCA
    “OVIDIUS” UNIVERSITY CONSTANTA, 124, MAMAIA BLD., 8700 CONSTANTA
  • ZAHARIA ANIŞOARA ARLEZIANA
    “OVIDIUS” UNIVERSITY CONSTANTA, 124, MAMAIA BLD., 8700 CONSTANTA

Abstract

A new type of structured packing made of corrugated metal gauze was tested in a liquid - liquid countercurrent contactor at the extraction of some mercaptans (Ethanethiol, 1-Propanethiol and 1-Butanethiol) from gasoline with NaOH solutions (5%, 10% and 15% wt). The study was made in a laboratory installation, comparatively with the contactor without packing, acting as a dispersion column. The new packing has a great void fraction but a small specific area. However, it has sensibly better efficiency in the extraction process, proved by increasing up to 56% the mass transfer coefficients.

Cuvinte cheie

mass transfer liquid- liquid extraction structured packing