MEASURING NOISE LEVEL IN THE TEXTILE INDUSTRY

  • CLAUDIA TOMOZEI
    “Vasile Alecsandri” University of Bacau, Calea Marasesti 157, Bacau, 600115, Romania
    claudia.tomozei@ub.ro
  • ALEXANDRA PIPA
    “Vasile Alecsandri” University of Bacau, Calea Marasesti 157, Bacau, 600115, Romania
  • OANA IRIMIA
    “Vasile Alecsandri” University of Bacau, Calea Marasesti 157, Bacau, 600115, Romania
  • MIRELA PANAINTE-LEHADUS
    “Vasile Alecsandri” University of Bacau, Calea Marasesti 157, Bacau, 600115, Romania
  • FLORIN NEDEFF
    “Vasile Alecsandri” University of Bacau, Calea Marasesti 157, Bacau, 600115, Romania

Abstract

The Company SС Sonomа Trаding currently owns a production area, the activity being carried out on a placement has a built area of 275 m2. The monitoring of the noise level within the company Sonoma Trading SRL was carried out for three weeks, between 18.05.2015 - 5.06.2015; for the noisiest equipments. Result of noise level was in the range 82.41 dB – 63.73 dB. The background noise was 38.59 dB. Based on the results of the measurements made, the noise map for both tailoring rooms was prepared: the tailor room and the ironing - stapled - packing section. According to the obtained results, the noise level values within the company Sonoma Trading SRL do not exceed the maximum allowed imposed by the legislation in force.

Cuvinte cheie

noise level noise control tailoring noisy machines